Offical web
Help
分享晒单
Welcome to PCsensor!
Button Text
Product Category
TEMPerX232 Secondary Development document_English
source: | author:pcsensor | release time :2021-10-15 | 118 browse times: | Share:
TEMPerX232 Secondary Development document_English

TEMPerX232 Secondary Development document_English


COM Configuration:

     Mode:       ASCII

         Baud Rate:  9600bps

         Data Bit:   8

         Parity Bit: None

         Stop Bit:   1

        

communication:

Reading temperature and humidity:

        PC send command:ReadTemp

    PC response data:type:xx.xx [C],xx.xx [%RH]<


            

    type:    "Temp-Inner"    

        "Temp-Outer"     

             "unknow!"  No type identified  

        Attention:xx.xx represent for value


Reading calibration:

    PC send command:ReadCalib

    PC response data:type-Calib:xx.x [C],xx.x [%RH]<

                

            

    type:    "Inner"    

        "Outer"     

             "unknow!"  No type identified 

    

Setting calibration:

    PC send command:SetCalib-type:xx.x,xx.x>

            

    PC response data:Setting successful  type:OK,OK


                          Error:              type:ERROR,ERROR


    type:    "Inner"    

        "Outer"     

  

    notes:For example:SetCalib-Inner:1.0,1.1>  Calibration value is -10.0~10.0


Reading probe type:

    PC send command: ReadType

    PC response data: Type:type


    type:     "Inner-H2"

        "Inner-H7"

        "Outer-Dx"

        "Outer-Tx"

        "Outer-H1" 

        "Outer-H2"                

                



Reading temperaure alarm value:

    PC send command:ReadAlert-Temp

    PC response data:TempUpperAlert-Inner:xx.xx [C]   TempLowerAlert-Inner:xx.xx [C]

                  TempUpperAlert-Outer:xx.xx [C]   TempLowerAlert-Outer:xx.xx [C]


Setting temperaure alarm value:

    PC send command:SetTempUpperAlert-type:xx.xx>

                 SetTempLowerAlert-type:xx.xx>

            

    type:  "Inner"

            "Outer"


    PC response data:Setting successful OK

                 Setting fail       ERROR


    notes:the range of inner temperature alarm value is -40.00 ~ 85.00[C],the range of outer temperature alarm value is -4.00~125.00[C]


Reading humidity alarm value:

    PC send command:ReadAlert-Hum

    PC response data:HumUpperAlert-Inner:xx.xx [%RH]   HumLowerAlert-Inner:xx.xx [%RH]

                 HumUpperAlert-Outer:xx.xx [%RH]   HumLowerAlert-Outer:xx.xx [%RH]



Setting humidity alarm value:

    PC send command:SetHumUpperAlert-type:xx.xx>

                 SetHumLowerAlert-type:xx.xx>

            

    type:  "Inner"

            "Outer"


    PC response data:Setting successful OK

                  Setting fail       ERROR


    notes:the range of humidity alarm value is 00.00 ~ 99.00[%RH]


Setting temperature pattern:

    PC send command:SetMode-Temp:x>    

    PC response data:successful OK

                  fail       ERROR

    notes:x=0 means select degrees Celsius pattern  x=1 means select Fahrenheit degree pattern


Reading temperature pattern

    PC send command:ReadMode-Temp   

    PC response data:TempMode:type

    type:0

          1                


Reading version:

    PC Send command:Version

    PC response data:TemperX232_V1.8


Clear calibration and alarm value:

    PC send command:EraseFlash

    PC response data:OK


Help command:Help or?